Background

The pressure switch is a normally closed (low air pressure) switch that connects via a 3.5 mm jack into the back of the mounting plate on Legacy ATC’s. On the M style tool changers, they are located on the underside of the ATC electrical box, and are connected with two wire leads directly to the ATC board. When the switch has above 90 PSI it opens. The ATC control board looks for this open signal to indicate there is adequate air pressure.

Air Pressure
Image Added

Switch State

Error

<90 PSI

Closed

Low Air Warning

>90 PSI

Open

Nothing

Image Removed
Image Added
Image Added

Table of Contents

Table of Contents
minLevel2
maxLevel7
stylenumber

Disconnect and/or replace the sensor

Reason: The air pressure sensor is faulty.

  1. Disconnect the 3.5 mm jack or remove the two wire leads from the ATC board, which opens the circuit and allows the machine to run.

Recalibrate the sensor

Reason: The air pressure sensor needs to be calibrated.

  1. Remove the boot and adjust the switches threshold through an adjustment screwThere is an adjustment screw under the rubber boot in the back of the machine for the pressure sensor. Set your regulator at the lowest pressure your air system provides and turn the screw until the “Air Pressure” LED on the status tab turns green. Inward should set it to a higher pressure and outward should it to a lower pressure.

Replace the sensor

Reason: There is a short in the circuit.

  1. Find and repair the short.

  2. (warning) An extreme solution that my be irreversible would be to cut the wires connecting the female 3.5 mm jack to the ATC control board and use wire nuts or electrical tape to cap them off. As long as the short was past where you cut, you will break the circuit and the ATC control board will see the “open” it needs to operate. (warning)