The ohmic probing system on the 1300PL relies on a calibrated resistance value between the torch cap and the workpiece. If you do not calibrate your ohmic probe, you may find that it is triggered by water on the work piece workpiece or inside the torch cap.
Tools
Phillip’s Phillips head screwdriver
Step 1
Open the electrical cabinet and identify the Tormach TCHT Board (PN 39096).
...
Depending on which revision of the board you have, the sensitivity potentiometer will look different.
...
If the LED did not light up, identify adjustment screw RV1 on the TCHT board (indicated in the image above). Increase the sensitivity by rotating the screw clockwise, 1/16th turn at a time, until the workpiece is detected.
...