Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

In This Section, You'll Learn:

...

  • Allows for unrestricted access to machine controls.

  • Conforms to the following:

    • Primary Power Required Single-Phase 230 Vac, 50/60 Hz

      • Maximum 240 Vac, 50/60 Hz

    • Recommended Circuit Amperage Dedicated 20 A breaker

      • Maximum 60 A breaker

NOTE: For more information, see "Electrical and Power Requirements"

  • Has clean, dry, compressed air.

  • Has one continuous slab sufficient to support the weight of the machine, accessories, and any additional equipment.

  • Is a dry, properly ventilated, and well-lit internal space that conforms to the following temperature and humidity requirements:

    • Operating Temperature Range 40°F-100°F (5°C-38°C)

    • Humidity Range 5%-95% (non-condensing)

  • Provides for unobstructed machine motion and operation.

...

If a pallet is too wide to fit through a doorway, see Moving Dimensions (D40147).

Operator Workstation Reference

...

Buck-Boost Transformer Used to adjust line voltages. While the machine can run on line voltages between 200 to 240 Vac, spindle performance is reduced on line voltages below 230 Vac, and damage to electrical components is possible on line voltages above 240 Vac. To prevent reduction in spindle performance or damage to electrical components, we recommend the Buck-Boost Transformer (PN 32554).

Looking for more information?

This is a section of the 1100MX operator's manual. To view the whole manual, go to Tormach document UM10586.

If you have additional questions, we can help. Create a support ticket with Tormach Technical Support at tormach.com/how-to-submit-a-support-ticket for guidance on how to proceed.