  1. Power on the machine and take it out of reset.

  2. Examine the green LED on the DC-BUS board.

    1. If the green LED is not illuminated: Go to https://tormach.atlassian.net/wiki/spaces/1100MX/pages/3602186609/All+Axes+Won+t+Move+When+Commanded

    2. If the green LED is illuminated: Continue to the next step.

  3. Power off the machine.

  4. Remove the cover from the DC-BUS board.

  5. Using the table below, locate the corresponding axis fuse and measure its resistance across the fuse with a digital multimeter set to resistance.

    1. Replace the fuse if the digital multimeter reads OL, shows a resistance in the MΩ, and/or doesn’t produce continuity tone.

      image-20240108-222001.pngImage Added
    2. If the fuse measures 0-5 Ω, reinstall it.

...