Power on the machine and take it out of reset.
Examine the green LED on the DC-BUS board.
If the green LED is not illuminated: Go to https://tormach.atlassian.net/wiki/spaces/1100MX/pages/3602186609/All+Axes+Won+t+Move+When+Commanded
If the green LED is illuminated: Continue to the next step.
Power off the machine.
Remove the cover from the DC-BUS board.
Using the table below, locate the corresponding axis fuse and measure its resistance across the fuse with a digital multimeter set to resistance.
Replace the fuse if the digital multimeter reads OL, shows a resistance in the MΩ, and/or doesn’t produce continuity tone.
If the fuse measures 0-5 Ω, reinstall it.
...