Verify the Installation
...
Use a multimeter to verify that the electrical service in your location meets the following requirements. If your location does not meet these requirements, do not install the machine. Instead, you must consult with a local electrician about your options.
Primary Power Required Single-Phase 230 Vac, 50/60 Hz
NOTE: Single-phase 120 Vac minimum when on 50 Hz.Recommended Circuit Amperage Dedicated 20 A breaker
Connect the machine's mains power cable to the verified electrical service.
Find the Main Disconnect switch, and then remove the hang tag (if present).
...
Turn the Main Disconnect switch to ON.
...
Mains power is now connected to the machine.
Push the Power button on the PathPilot controller, if it's not already powered on.
Push the Power button on the monitor, if it's not already powered on.
Follow the on-screen instructions to configure the PathPilot operating system and PathPilot controller.
When configuration is complete, the PathPilot operating system launches.
NOTE: After you first configure PathPilot, the operating system automatically launches whenever it's powered on.Depending on which monitor you have, do one of the following:
Standard Monitor Go to the next step.
Touch Screen Monitor You must first make sure that the monitor is configured and calibrated. From the PathPilot interface, in the MDI Line DRO fieldDRO field, type Admin Touchscreen. Then, select the Enter key, and follow the on-screen instructions.
Rotate the Emergency Stop button on the operator box one-quarter turn clockwise to release it.
...
Push the blue Reset button to enable the machine.
...
The axis drives are now powered on.
Verify that the blue Reset LED on the operator box comes on. From the PathPilot interface, on the Status tab, verify that the Machine OK light changes from yellow to green.
Once both are on, the machine is powered on and ready to operate.
...
Power Off the Machine
Push the Emergency Stop button on the operator box to lock it into the disabled position.
...
With the Emergency Stop button in the disabled position all motion and spindle function stops, and the Reset button is disabled. On the operator box, the blue Reset LED goes off. From the PathPilot interface, on the Status tab, the Machine OK light illuminates yellow.
...
This is a section of the 770MX operator's manual. To view the whole manual, go to Tormach document UM10587.
If you have additional questions, we can help. Create a support ticket with Tormach Technical Support at tormach.com/how-to-submit-a-support-ticket for guidance on how to proceed.