Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Verify the Installation

...

  1. Turn the Main Disconnect switch to ON.

...

Mains power is now connected to the machine.

  1. Push the Power button on the PathPilot controller, if it's not already powered on.

  2. Push the Power button on the monitor, if it's not already powered on.

  3. Follow the on-screen instructions to configure the PathPilot operating system and PathPilot controller.
    When configuration is complete, the PathPilot operating system launches.
    NOTE: After you first configure PathPilot, the operating system automatically launches whenever it's powered on.

  4. Depending on which monitor you have, do one of the following:

    1. Standard Monitor Go to the next step.

    2. Touch Screen Monitor You must first make sure that the monitor is configured and calibrated. From the PathPilot interface, in the MDI Line DRO field, type Admin Touchscreen. Then, select the Enter key, and follow the on-screen instructions.

  5. Rotate the Emergency Stop button on the operator box one-quarter turn clockwise to release it.

...

  1. Push the blue Reset button to enable the machine.

...

The axis drives are now powered on.

  1. Verify that the blue Reset LED on the operator box comes on. From the PathPilot interface, on the Status tab, verify that the Machine OK light changes from yellow to green.
    Once both are on, the machine is powered on and ready to operate.

...

  1. From the PathPilot interface, select Exit.

  2. When prompted, select OK.

  3. Once the PathPilot interface indicates that it's safe to power off the machine, turn the Main Disconnect switch to OFF.

...

Mains power is disconnected from the machine.

Verify Limit Switch Function

...

  1. Power on the machine and bring it out of Reset.

  2. Select the Page Up key on the keyboard to move the spindle head up (Z+).

  3. Remove and discard the shipping block from the machine table.

  4. Reference the axes: from the PathPilot interface, select Ref Z, Ref X and Ref Y.

...

The machine moves to the reference position.

  1. Use the keyboard to verify axes motion:

    1. Select the Right Arrow key and then the Left Arrow key.
      The table moves left (X+), then right (X-).

    2. Select the Down Arrow key and then the Up Arrow key.
      The table moves away from you (Y-), then toward you (Y+).

    3. Select the Page Down key and then the Page Up key.
      The spindle head moves down (Z-), then up (Z+).

  2. If applicable, verify the optional Jog Shuttle:

    1. Press any axis button on the Jog Shuttle — X, Y, Z, or A — to select an axis.

...

  1. From the PathPilot interface, in the RPM DRO field, type 500. Then select the Enter key.

  2. Select FWD.

...

The spindle rotates clockwise (viewed from above) at 500 rpm.

  1. Select STOP.
    The spindle stops rotating.

  2. Select REV.
    The spindle rotates counterclockwise (viewed from above) at 500 rpm.

  3. Select STOP.
    The spindle stops rotating.

  4. In the RPM DRO field, type 1000. Then select the Enter key.

  5. Select FWD.
    The spindle rotates clockwise (viewed from above) at 1000 rpm.

  6. Repeat the procedure at 1000 rpm.

...