  1. If you have voltage at the board but no lights, estop the machine, then remove components from the board one at a time, . (excluding the incoming power) Then power back up, to vet if a component is shorting the board.

  2. If you do not have +48 Vdc across wires 200 and 201, move to the 48V Power Supply in the machine column. Measure for 48V DC on the power supply from the V+ and V- wires from the ATC.

...

  1. If you have +48 Vdc at wires 204 and 205 at the ATC control board but no lights on the board, estop the machine, then remove components from the board one at a time, . (excluding the incoming power) Then power back up, to vet if a component is shorting the board.

  2. If you do not have +48 Vdc across wires 204 and 205, move to the 48V Power Supply in the machine column. Measure for 48V DC on the power supply from the V+ and V- wires from the ATC.

  3. If you continue to experience the check fuses and cabling error, contact Tormach Tech Support.

...