Your ATC board should show the following LEDs lit if it has +48 Vdc at wires 503 and 504 at the ATC control board and is successfully talking to PathPilot.
...
If you have +48 Vdc at wires 503 and 504 at the ATC control board but no lights on the board, contact Tormach Tech Support.
If you do not have +48 Vdc across wires 503 and 504, move to the 48V Power Supply in the machine column. Measure for 48V DC on the power supply from the V+ and V- wires from the ATC.
If the ATC won’t communicate and the ATC tab goes away, but the power drawbar opens/closes and the Status tab shows when the USB is removed and replaced, then inspect the RJ11 (DB3) cable for damage. Reseating and/or replacing this cable may be necessary as it may have became damaged or have an intermitted short.
...
If you continue to experience the check fuses and cabling error, contact Tormach Tech Support.
...