Even with all of these components, you can systematically locate nearly any problem with just a multimeter.
Tools
Digital multimeter
Twist
...
Out the Emergency Stop
...
Button
Reason: The Emergency Stop button is pushed in.
...
Info |
---|
The Reset button doesn't illuminate until after you:
|
Reset the
...
Building’s Mains Breaker
Reason: The shop or building’s mains breaker is turned off.
Examine the building’s breaker. If it's not already on, turn it on.
Using a digital multimeter, measure to inspect and verify that you have power at the outlet.
Inspect the
...
Power Entering the
...
Machine
Reason: The Main Disconnect switch is in the Off position.
...
Machine | Wires | Measure for… |
---|---|---|
1100M/MX | 102/N and 103 | 230 Vac nominal |
...
Reset the CB1 and/or CB2
...
Circuit Breaker
Reason: The CB1 and/or CB2 circuit breaker tripped.
...
Machine | Wires (CB1 and CB2) | Measure for… |
---|---|---|
1100M/MX | 105 and 104/N and 107 and 106/N | 230 Vac nominal |
...
Inspect the DC
...
Power Supply (PS1)
Reason: The DC power supply PS1 is defective.
...
Machine | Wires | Measure for… |
---|---|---|
1100M/MX | 112/N and 113 | 220 Vac nominal |
...
Inspect the K1
...
Contactor
Reason: The contactor K1 is defective.
...