Even with all of these components, you can systematically locate nearly any problem with just a multimeter.

Tools

  • Digital multimeter

Twist

...

Out the Emergency Stop

...

Button

Reason: The Emergency Stop button is pushed in.

...

Info

The Reset button doesn't illuminate until after you:

  1. Twist out the Emergency Stop button.

  2. Press the Reset button.

Reset the

...

Building’s Mains Breaker

Reason: The shop or building’s mains breaker is turned off.

  1. Examine the building’s breaker. If it's not already on, turn it on.

  2. Using a digital multimeter, measure to inspect and verify that you have power at the outlet.

Inspect the

...

Power Entering the

...

Machine

Reason: The Main Disconnect switch is in the Off position.

...

Machine

Wires

Measure for…

770M/MX

101 and 100/N

115 Vac nominal

...

Reset the CB1 and/or CB2

...

Circuit Breaker

Reason: The CB1 and/or CB2 circuit breaker tripped.

...

Machine

Wires (CB1 and CB2)

Measure for…

770M/MX

105 and 100/N

and

107 and 100/N

115 Vac nominal

...

Inspect the DC

...

Power Supply (PS1)

Reason: The DC power supply PS1 is defective.

...

Machine

Wires

Measure for…

770M/MX

112/N and 113

115 Vac nominal

...

Inspect the K1

...

Contactor

Reason: The contactor K1 is defective.

...