  1. Examine the Main Disconnect switch. If it’s not already in the On position, turn it on and try to take your machine out of reset.

  2. Measure the voltage coming out of your Main Disconnect switch.

  3. Identify the wires as indicated in the table.

    1. If you measure the correct Vac, continue.

    2. If you do not any Vac, you either have a loose wire or a faulty Main Disconnect switch.

Machine

Wires

Measure for…

1100M/MX

102/N and 103

230 Vac nominal

...