Reason: Control signals aren’t reaching the electronic driver modules.
Inspect the stepper driver controller lights.
Some controller lights are on: One Axis Won't Move (or Only Moves in One Direction), and Other Axes Move.
All the controller lights are off: Continue to the next step.
Power off the machine.
Examine the data cable at the machine control board and the axes drivers.
Machine control board: 26 pin IDC (ribbon cable); J6
Stepper driver controllers: 10 pin IDC (ribbon cable)
J6-1 - J6-6 (X-axis)
J6-7 - J6-12(Y-axis)
J6-13 - J6-18 (Z-axis)
...
Examine the power and control cables at the DC-BUS and the stepper driver controllers removing, inspecting, and re-connecting them to ensure they are seated.
DC-Bus/Stepper driver controllers: Spade connectors/Degson style
302/303 (X-axis)
304/305 (Y-axis)
306/307 (Z-axis)
...
If there is any discoloration, replace the cable and driver.
Continue to the next troubleshooting topic.
Inspect the Motor’s Drivers
...