This section covers required site preparations prior to placing PCNC mill in service.
...
Minimum floor space requirements are as follows:
Width | Depth | Height | |
PCNC 1100 | 67” | 43” | 84” |
PCNC 770 | 60” | 40” | 73” |
NOTE: Allocate additional space to allow access to rear of mill for maintenance or repairs.
...
WARNING! Electrical Shock Hazard: Electrical connections must be performed by a certified electrician. Failure to do so may result in injury or death.
Primary | Secondary | Recommended Circuit Amperage | |
PCNC 1100 | 200-250 VAC, 50/60 Hz | 115 VAC, 50/60 Hz | 20 A primary 15 A secondary |
PCNC 770 | 115 VAC, 50/60 Hz | N/A | 20 A |
Grounding
All power inputs to PCNC mills must be properly grounded. Check continuity between bare metal on mill frame and true earth ground (water pipe or similar) to ensure proper grounding.
...
A Quick 220™ voltage converter can be used to convert voltages from two out-of-phase 115 VAC circuits to a single 230 VAC output. This option may be of interest to PCNC 1100 owners with sites that do not allow for 230 VAC service (PN 33972).
Looking for more information?
This is a section of the PCNC 1100 operator's manual. To view the whole manual, go to Tormach document UM10349.
If you have additional questions, we can help. Create a support ticket with Tormach Technical Support at tormach.com/how-to-submit-a-support-ticket for guidance on how to proceed.
...