Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

IMPORTANT! Please read this section before you begin installing your Automatic Tool Changer (ATC).

...

Product Information

Product: Automatic Tool Changer (ATC) for 1100M (PN 38400)

The Automatic Tool Changer (ATC) holds up to 12 tools in a single tray. If your program requires more tools, the ATC changes tools automatically for all tools assigned to the tray, and pauses for a manual tool change for all tools not assigned to the tray.

...

NOTE: If any items are missing, we can help. Create a support ticket with Tormach Technical Support at tormach.com/how-to-submit-a-support-ticket for guidance on how to proceed.

...

  • Air Pressure Between 90 psi and 120 psi (620 kPa to 825 kPa).

  • If the air supply is more than 120 psi (825 kPa), you must use a regulator.

  • Air Volume For successive back-to-back tool changes, at least 2 cfm at 90 psi is required.

  • Exact air volume depends on the frequency of tool changes.

  • Dry Air We recommend using a compressed air dryer, desiccator, or filter between the air compressor and the machine.

  • Lubricated Air You must lubricate the air with air tool oil.
    Use the FRL Filter-Regulator-Lubricator (PN 32457) (included with the power drawbar kit) for this purpose.

...

NOTE: If the VFD Running light did not come on in the previous step, we can help. Create a support ticket with Tormach Technical Support at tormach.com/how-to-submit-a-support-ticket for guidance on how to proceed.

...