Dark - the estop circuit has been interrupted
Solid - communication with Pathpilot has dropped
Blinking 50/50 on/off - VFD has faulted
Blinking 10/90 on/off - turret tool change has failed
...
Estop circuit has been interrupted
...
Verify that there are no physical obstructions that the turret could have hit
Verify that the turret is filled with oil
Oil for Gen 1 turret
Oil for Gen 2 turret
If the turret does not turn at all: verify that the turret control board is receiving power on J14-4 and J14-5.
Verify that the F1 and F2 fuses on the turret control board have a reading between 0.1 and 1 ohm. Below or above 0.1 to 1 ohm indicate a fuse that needs to be replaced.
Gen 2 - Verify that the motor will turn by taking the belt off and command a tool change
If the turret will turn forward but will not turn in reverse, the lock switch may need to be adjusted
Lock switch adjustment procedure for Gen 1 turret