  1. Power on the machine and take it out of reset.

  2. Inspect the K1 for an illuminated red LED that indicates it has power.

    1. If the light is on: The K1 is latched. Using a digital multimeter set to Vac, measure for 220 Vac between:

      1. 114N

      2. 115

    2. If the light is not on: Continue to the next step.

      image-20240108-222418.png
  3. Press and hold the Reset button on the operator box and observe the K1 LED. Then release the Reset button and observe the K1 LED.

    1. If the light only stays on when the button is pressed: There is a loose coil wire, short, or the K1 has malfunctioned.

    2. If the light never comes on: Go back to the previous troubleshooting topics to ensure your machine is receiving power. See Machine Won't Power On - 1100MX