1.  Configure PathPilot for the xsTECH electronic tool setter

On the Settings tab, choose Passive Probe as the accessory input logic.

PASSIVE_PROBE_CONFIG.png

2.  Test ETS function

Select the PROBE/ETS Tab, then select ETS SETUP

To test, plug in the ETS and press down the the sensor.  The Accessory Input LED on PathPilot should change to green when the sensor is pressed.  If it does not, do not continue -  there is a problem with the ETS.

TEST_PROBE.png

3. Set ETS reference height

A. Remove the tool and spindle nut.  Position Spindle over the ETS so that the edge of the spindle will contact the tool setter.

TOOL_SETTER_HEIGHT_REFERERNCE.jpg

B. Press Move and Set ETS Button

xs.jpg

(VIDEO)

4.  Set G37 ETS Position

A. Place Tool in spindle and position it so it is directly over the tool setter.

ETS_BELOW.png

B. Move Z-axis so it is at the upper limit of its travel.  

ETS_ABOVE.png

C. Press SET G37 ETS POSITION to store this position as the tool setter location.

ETS_POSITION.png

You are now ready to use the tool setter.  The set the length of a tool, follow the procedure below

5.  Set tool length

A. Place the tool you wish to measure into the spindle 

B. Go to the Offsets Tab and Press MOVE & SET TOOL LENGTH.  The spindle will move towards the tool setter and execute the tool touch-off routine.