Background

As motors rotate and the machine cuts, vibrations are created. While these are normal, they can resonate, making it sound like something is wrong. Loose sheet metal won’t affect your machine performance, but there are other electrical and mechanical components that should be inspected if the noise doesn’t subside.

Tools

  • Small flat-bladed screwdriver

Secure loose sheet metal

Reason: There is loose sheet metal.

  1. Feel for vibration on the sheet metal by placing your hand on the enclosure, outside of the electrical cabinet, chip tray, or any other location you think is practical.
    If the vibration dissipates then the problem is not with the motors.

Reseat the connectors on the machine control board and motors

Reason: Control signals aren't reaching the electronic driver modules/servo motors.

  1. Power off the machine.

  2. Examine the data cables at the machine control board and the servos removing then re-connecting them to ensure they are seated.

    1. Machine control board: Degson style

      1. 424 (J13) (X-axis)

      2. 425 (J14) (Y-axis)

      3. 426 (J15) (Z-axis)

    2. Servos: Molex style

image-20240130-174038.png
  1. Examine the power cables at the DC-BUS and the servos removing then re-connecting them to ensure they are seated.

    1. DC-Bus: Spade connector

      1. 210/211 (X-axis)

      2. 220/221 (Y-axis)

      3. 230/231 (Z-axis)

    2. Servos: Molex style

image-20240130-174329.png
  1. Continue to the next troubleshooting topic.

Inspect the DC-BUS capacitor (C1)

Reason: The C1 (DC-BUS) capacitor is defective.

  1. Power off the machine. Then, unplug the green power connectors on all of the axis drivers (X, Y, Z, and A).

  2. With the electrical cabinet door open, power on the machine.

  3. Examine the green LED on the DC-BUS board, and then twist out the Emergency Stop button and press the Reset button. The green LED should come on.

  4. Push in the Emergency Stop button.

    1. If the LED goes out in two seconds or less, the capacitor is defective and must be replaced. If the LED takes five seconds or more to go out, the capacitor is OK.

  5. If the results are not conclusive, power off the machine. Then, unplug the green power connectors from the axis drivers (if they're not already unplugged).

  6. Power on the machine). Then, carefully measure DC voltage on wires 202 (common) and 203 on the DC-BUS board.

    1. If there's a DC voltage of a nominal 65 Vdc (55-75), this indicates the capacitor is OK.

    2. If there's a DC voltage of a nominal 40 Vdc (35-45), this indicates the capacitor is defective.

image-20240130-182358.png

Inspect the axis brake

Reason: The axis brake is failing.

  1. With a multimeter, check for 24Vdc between wires 435 and 400 on the ECM board.

  2. If 24 Vdc is not present, the relay on the ECM board has failed and the ECM board needs to be replaced. If 24 Vdc is present, the brake has failed and needs to be replaced.