15L Maintenance
Lathe Maintenance Schedule
Frequency | Completed | Item |
Daily |
| Check coolant level (12 gallon capacity) |
| Check oiler level and top off as needed (Auto Oiler 2.1 quarts / Manual Oiler 0.25 quart) | |
| Clean chips from ways and carriage | |
| Spray exposed, non-painted metal surfaces areas with WD-40® or similar to prevent rust | |
| ||
Weekly |
| Check/adjust draw tube tension on 5C lever closer (if applicable) |
| Clean chip basket on coolant tank | |
| Check air gauge/regulator for proper PSI (90 PSI minimum) | |
| Use mild cleaner to clean all exterior surfaces (no solvents) | |
| Check oil and grease reservoirs; top up as needed | |
| ||
Monthly |
| Dispose of oil in drain bucket |
| Remove coolant tank pump and clean out sediment buildup in tank; reinstall | |
| Inspect electrical cabinet vent(s) for dust build up; if necessary, wipe vents with clean cloth or use compressed air to remove dust if accumulation is excessive | |
| ||
Every Six Months |
| Inspect way covers as needed to ensure proper operation; replace as needed |
| Inspect oil system for blockages; clean/replace as needed | |
| Check lubrication hoses for signs of wear or cracking; replace as needed | |
| ||
Every 12 Months |
| Check limit switches for proper function; replace as needed |
| Check door switches for proper function; replace as needed | |
Looking for more information?
This is a section of the 15L operator's manual. To view the whole manual, go to Tormach document UM10225.