15L Maintenance

15L Maintenance

Lathe Maintenance Schedule

Frequency

Completed

Item

Daily

 

Check coolant level (12 gallon capacity)

 

Check oiler level and top off as needed (Auto Oiler 2.1 quarts / Manual Oiler 0.25 quart)

 

Clean chips from ways and carriage

 

Spray exposed, non-painted metal surfaces areas with WD-40® or similar to prevent rust

 

Weekly

 

Check/adjust draw tube tension on 5C lever closer (if applicable)

 

Clean chip basket on coolant tank

 

Check air gauge/regulator for proper PSI (90 PSI minimum)

 

Use mild cleaner to clean all exterior surfaces (no solvents)

 

Check oil and grease reservoirs; top up as needed

 

Monthly

 

Dispose of oil in drain bucket

 

Remove coolant tank pump and clean out sediment buildup in tank; reinstall

 

Inspect electrical cabinet vent(s) for dust build up; if necessary, wipe vents with clean cloth or use compressed air to remove dust if accumulation is excessive

 

Every Six Months

 

Inspect way covers as needed to ensure proper operation; replace as needed

 

Inspect oil system for blockages; clean/replace as needed

 

Check lubrication hoses for signs of wear or cracking; replace as needed

 

Every 12 Months

 

Check limit switches for proper function; replace as needed

 

Check door switches for proper function; replace as needed

Looking for more information?

This is a section of the 15L operator's manual. To view the whole manual, go to Tormach document UM10225.