Check the machine LED light on the electrical cabinet
Dark - the estop circuit has been interrupted
Solid - communication with Pathpilot has dropped
Blinking 50/50 on/off - VFD has faulted
Blinking 10/90 on/off - turret tool change has failed
Estop circuit is interrupted
Verify that the estop buttons have been released
Estop on the controller arm
Estop on the electrical cabinet
Check if there is a wiring issue in the estop circuit
Communication issues
Verify that there is conductivity on each pin of the DB25 and J4 cables
check Mesa board for solid red LED’s
VFD fault
Check the VFD display for the cause of the fault
Turret tool change has failed
Check for physical obstructions to tool change (like a part or chuck)
Turret lock switch adjustment (if turret reverses)
Gen 1 turret
Gen 2 turret
Turret control board/main control replacement (if turret does not reverse)
Belt snapped
General
Content
Integrations