Power Off/Power On Procedure
Important! Do not power on the motors and drives via the green Start button before powering on the controller that oversees their operation. Make sure that the controller is on and the PathPilot interface is loaded before powering on the mill. Likewise, make sure to depress the red E-Stop before powering off the controller using the Exit button on the PathPilot interface. Confirm that the mill powers off and on correctly using the procedure detailed in this section.
Power Off/On Procedure | ||
Power Off |
| |
| ||
| ||
Power On |
|
|
| ||
| ||
|
Initial PathPilot Controller Configuration
WARNING! Unattended Operation: Machine is not designed unattended. Do not leave machine unattended during operation. When machine is not in use, turn the main disconnect off. Failure to do so could result in death, serious injury, and/or machine damage.
Turn the Main Disconnect switch to On. Turn the operator panel-based Controller switch, used to power the controller on and off, to the On position.
The first time the PathPilot controller is powered on it starts a configuration process that allows the operator to configure the PathPilot operating system to the particular machine. Follow the on-screen instructions to complete controller configuration. After configuration, PathPilot automatically launches; the controller automatically loads PathPlot for the selected machine when the controller is powered on in the future.
Looking for more information?
This is a section of the PCNC 770 operator's manual. To view the whole manual, go to Tormach document UM10350.