One Axis Won't Move (or Only Moves in One Direction), and Other Axes Move - 1100M
Background
Your machine axes require power and control signals to work. If either of those are disrupted you can lose any or all axis motion. If all of your motors are not working, go to All Axes Won't Move When Commanded.
Tools
Digital multimeter
Small flat-bladed screwdriver
Metric hex wench set
Phillips screwdriver
Reseat the Connectors on the ECM Board and Motors
Reason: Control signals aren't reaching the electronic driver modules.
Power off the machine.
Examine the data cable at the machine control board and the axes drivers.
Machine control board: 26 pin IDC (ribbon cable); J6
Stepper driver controllers: 10 pin IDC (ribbon cable)
423.1 (X-axis)
423.2 (Y-axis)
423.3 (Z-axis)
Â
Â
Â
Â
Â
Examine the power and control cables at the DC-BUS and the stepper driver controllers removing, inspecting, and re-connecting them to ensure they are seated.
DC-Bus/Stepper driver controllers: Spade connectors/Degson style
210/211 (X-axis)
220/221 (Y-axis)
230/231 (Z-axis)
If there is any discoloration, replace the cable and driver.
Continue to the next troubleshooting topic.
Inspect the Motor’s Drivers
Assess the State of the Motor or Stepper Driver Controller
Reason: There's a defective or malfunctioning axis driver/cable.
Power on the machine and take it out of reset.
Examine the LEDs of the stepper driver controllers.
If the stepper driver controller has an illuminated green light: It is ready and operating normally.
If the stepper driver controller has an illuminated red LED: The machine should be power cycled to try and reset the stepper driver controller or the stepper driver controller needs to be replaced.
If the is no light on the stepper driver controller: Continue to the next troubleshooting topic.
Full Stepper Driver Controller Swap (Full Driver Swap) NOTE: 4th AXIS DRIVERS CANNOT BE SWAPPED WITH SERIES 3 OR 'M' SERIES MACHINE DRIVERS.
Power off the machine.
Identify the stepper driver controller corresponding to the malfunctioning axis and its two sets of wires; a green power connector and 10 pin IDC (ribbon cable). Remove and examine them:
If there the connector appears burnt: Replace both the cable connector and driver.
If the cable and pins appear normal: Continue to the next step.
On the malfunctioning axis stepper driver controller, replace the ribbon cable connector power connector with those from a functioning axis driver.
There will be no change to how to jog the swapped axis.Power on the machine.
Jog the malfunctioning axis and swapped axis in both directions.
If the malfunctioning motor now functions properly: It is likely that the malfunctioning axis driver is defective.
If the malfunctioning motor continues to move erratically: Continue to the next troubleshooting topic; but, it is likely that the malfunctioning axis motor is defective.
Half Stepper Driver Controller Swap (Half Driver Swap)
Power off the machine.
Verify that the wires and cables are in their original position.
Swap the ribbon cables between the malfunctioning stepper driver controller and a known good stepper driver controller.
The controls on the machine change, depending on the ribbon cables you swapped.Jog the malfunctioning axis in both directions.
If the malfunctioning motor now functions properly: It is likely the ribbon cable or control board are malfunctioning.
If the malfunctioning motor continues to move erratically: Continue to the next troubleshooting topic; but, it is likely that the malfunctioning axis motor is defective.
Inspect the DC Power Supply
Reason: There's a blown fuse on the DC-BUS board.
Power on the machine and take it out of reset.
Examine the green LED on the DC-BUS board.
If the green LED is not illuminated: Go to All Axes Won't Move When Commanded - 1100M
If the green LED is illuminated: Continue to the next step.
Power off the machine.
Remove the cover from the DC-BUS board.
Using the table below, locate the corresponding axis fuse and measure its resistance across the fuse with a digital multimeter set to resistance.
Replace the fuse if the digital multimeter reads OL, shows a resistance in the MΩ, and/or doesn’t produce continuity tone.
If the fuse measures 0-5 Ω, reinstall it.
Function | Fuse Number | Amperes | Speed |
---|---|---|---|
X-Axis | F1 | 8 A | Fast |
Y-Axis | F2 | 8 A | Fast |
Z-Axis | F3 | 8 A | Fast |
A-Axis | F4 | 8 A | Fast |
Main DC-BUS fuse | F6 | 10 A | Slow |
ATC | F8 | 5 A | Fast |
A blown fuse can be the result of a deceive driver or wiring. Inspect the axis' wiring carefully and repair any damage observed. If you replace a fuse and it immediately blows, it's likely a defective axis drive or its wiring.
Inspect the Motor
Reason: There's a defective motor or motor connection.
Power off the machine.
Remove the motor leads from the axis stepper driver controller, and examine the motor for signs of coolant or contamination.
If there is coolant or contamination: Replace the stepper driver controller and cable.
If there is nothing: Continue to the next step.
Based off of the chart, measure the resistance of windings at the green connector on the axis driver.
If the resistance is out of spec: Then the motor is defective.
If the resistance is within spec: Then inspect the cable and connectors between the axis motor and axis driver.
Axis | Probe | Resistance | |
---|---|---|---|
From (black probe) | To (red probe) | ||
X | 212 212 213 | 213 214 214 | 0.5-2.0 Ω |
Each wire | Ground (bare metal or wire labeled PE) | >1 M Ω or OL | |
Y | 222 222 223 | 223 224 224 | 0.5-2.0 Ω |
Each wire | Ground (bare metal or wire labeled PE) | >1 M Ω or OL | |
Z | 232 232 233 | 233 234 234 | 0.5-2.0 Ω |
Each wire | Ground (bare metal or wire labeled PE) | >1 M Ω or OL |
Resistance across leads on all phases for X, Y and Z should be about the same. Deviation may indicate a problem. This does not apply to the A-axis.
Inspect the Motor Coupling
Reason: There's a loose axis motor coupling.
Jog the axis and listen to determine if you can hear the motor run.
Remove the cover plate over the coupling and make witness marks across the coupling and ball screw.
Jog the axis to determine if the motor's turning but the screw isn't.
If the coupling is slipping, locate the hex screws and tighten them down.
Ensure Oil is Getting to the Motion System
Reason: Oil isn't getting to the ways and ball screw.
Examine the oil level in the oiler.
Investigate the oiling system for lack of oil and/or plugged lines (for more information, see Tormach service bulletin SB0031).
Push Fresh Oil Through the System
Reason: There's oil residue from long-term storage.
Repeatedly pump oil and slowly jog the axis.
If the machine has been sitting for a significant amount of time, the oil layer may have a suction effect.
Inspect the Gibs Position
Reason: The gibs are too tight.
Follow the gib adjustment procedure: Mill Gib/AC Bearing Adjustment and Backlash Compensation - 1100M
Clean the Ball Screw
Reason: There's debris on the ball screw.
Clean the ball screw.
Debris on the ball screws can rapidly accelerate wear and reduce the lifespan of your machine. Evaluate if additional measures are required to protect your machine's ball screws and ways (like supplemental dust collection).